HFIT 8.0 High Frequency High Voltage Insulation Tester,HF Leakage Current Tester

Mode:HFIT-8.0

Type:QA-Instruments

Contact:   ken@hkmedqc.com

HFIT 8.0 High Frequency High Voltage Insulation Tester is strictly developed in accordance with the IEC60601‑2‑2 (GB 9706.202‑2021) standard. It is specifically designed for the **high-frequency leakage current and high-frequency dielectric strength insulation tests** of high-frequency surgical accessories such as high-frequency electrosurgical instruments, laparoscopic instruments, and bipolar forceps. It is a compliant testing equipment for medical device R&D laboratories, production line quality inspections, and third-party testing institutions.

The Medteq HFIT 8.0 Insulation Tester, HFIT 8.0 High Frequency High Voltage Insulation Tester is the next generation product of the HFIT series, aiming to assess whether it complies with IEC 60601-2-2 insulation strength and cable leakage current tests. The standard model is designed for testing institutions that may need to handle various rated values ranging from 400Vp to 7200Vp. This model includes 4 modes, among which 2 have adjustable peak factors. Regardless of the rated value, its design can meet the requirements of the standard.


o High-frequency dielectric strength (e.g. IEC 60601-2-2:2009, Article 201.8.8.3.103)
o High-frequency leakage current (e.g. IEC 60601-2-2:2001, Clause 201.8.8.3.102)
o NE line insulation HF dielectric strength, cable leakage (IEC 60601-2-2, Article 201.15.101.4)


The HFIT 8.0 high-frequency high-voltage insulation tester has added the following new features to the existing HFIT 7.0:

Internal measurement and display:
Vpeak (+ Vp, -Vp)
Vrms
Peak factor
Irms, I reached the peak
Frequency
Peak factor target
Test time
Automatic mode: The user sets the target peak voltage, the system selects the mode, and adjusts the voltage and peak factor.
Timer function
Increased load capacity (150pF, up to 6kVp)

Core Advantages

 
1. 5 output waveforms are available: sine wave, modulated sine wave, wave cluster, high and low pulse waveforms, with a fully automatic test mode.
2. Output voltage range is 200 - 7200 Vp, with measurement accuracy of ±3% ±4V, covering the voltage range for most high-frequency surgical accessory tests.
3. Peak coefficient is continuously adjustable from 1.4 to 7.0, perfectly replicating the actual output waveforms of the electrosurgical device.
4. Real-time display on the screen: positive and negative peak voltage, RMS voltage, peak coefficient, leakage current, peak current, frequency, test timing.
5. High load capacitance capacity, supporting up to 150pF for long cable load testing.
6. Built-in dual BNC oscilloscope monitoring ports, eliminating the need for expensive high-voltage probes or current probes, and directly connecting an oscilloscope to observe the waveforms.
7. Auto mode: only set the target voltage, the instrument automatically matches the waveform and peak coefficient, and completes the compliance test with one click.
8. Multiple high-voltage safety interlock protections to avoid accidental high-voltage output and ensure the safety of operators.