The BPTM130 ultrasound soft tissue biopsy training module, the BPTM130 ultrasound-guided puncture model enables users to develop and practice the necessary skills to proficiently use ultrasound for imaging and surgical procedures. Using the Blue Phantom to simulate human tissue, this highly realistic and extremely durable soft tissue biopsy ultrasound surgical training model is ideal for training clinicians in the psychomotor skills related to ultrasound-guided fine needle biopsy procedures. These ultrasound imaging skills include: controlling the ultrasound system, positioning and moving the transducer, identifying soft tissue masses as tumors found in superficial anatomical structures, calculating the contours using the ultrasound system, and performing fine needle biopsy using ultrasound-targeted lesions.

This medical ultrasound training body model adopts the Blue Phantom patented ultra-durable tissue structure, which is extremely realistic in ultrasound imaging characteristics and feels like real human tissue. The BPTM130 ultrasound soft tissue biopsy training module, the BPTM130 ultrasound-guided puncture model contains various hypoechoic, hypoechoic and echo-transparent masses, allowing users to gain experience in using various lesions as they would in a clinical environment. Each model contains 16 different-sized masses - ranging from 4 millimeters to 11 millimeters - enabling users to develop their skills starting with larger lesions and targeting smaller masses as their skills progress.
 
Ultrasound Soft Tissue Biopsy Training Model BPTM130,Ultrasound Guided Puncture

 
The BPTM130 ultrasound soft tissue biopsy training module, the BPTM130 ultrasound-guided puncture model is highly suitable for new users as well as more experienced users who are improving their procedural skills. The masses in this soft tissue biopsy model can be accessed with a needle and liquid can be injected into the model to verify the needle tip position.
 
The fluid will automatically drain so that the model can be reused for training. We recommend using a sharp, non-bent needle of size 18 - 21 during training to maximize the self-repair and ultra-durability of the ultrasound training model. Although you can perform core biopsies and actually remove tissue from the model's tumor, it is important to know that each mass can only withstand a core biopsy until the lesion is damaged, which will require you to then move to another mass model in the training.
 
This medical simulation trainer will perform well with any ultrasound imaging system equipped with appropriate transducers (recommended ultrasound transducers; high-frequency linear array ultrasound probe 7.5 - 15 MHz). Our uncompromising quality enables clinicians to utilize this model and repeatedly practice the procedure without the high cost of replacing disposable parts. This ultrasound model is highly suitable for professionals, including breast surgery, surgical training programs, endocrinology training programs, radiology training programs, ultrasound training programs, simulation centers, technical skills centers, medical education facilities, and for ultrasound education and demonstrations by ultrasound manufacturers.

The BPTM130 ultrasound-guided puncture model specifications:

It is highly suitable for developing and improving the psychomotor skills related to ultrasound-guided soft tissue biopsy procedures.
It includes various high-echo, low-echo and echo-transparent masses, allowing users to gain experience in using various lesions, just as they would in a clinical environment.
It contains 16 different-sized masses - ranging from 4 millimeters to 11 millimeters - enabling users to develop their skills starting with larger lesions and target smaller masses as their skills progress.
Super durable design saves you money.
Self-healing tissue
Synthetic tissue never dries out
Boluses randomly appear throughout the simulated human tissue
Fluid can be injected into the model to verify the needle tip position (automatically expelled)
The convex surface contour provides a scanning environment similar to the human habit
Used with any ultrasound imaging system equipped with appropriate transducers
Practice using the ultrasound system control High quality
Patent technology
Dimensions: 7 inches x 5 inches x 2.5 inches (17 cm x 13 cm x 6 cm) (length x width x height)
Weight: 3.0 pounds. (1.4 kilograms.)

 

Photograph of the Physical Model of BPTM130 Ultrasound Guided Puncture:

 
Ultrasound Soft Tissue Biopsy Training Model BPTM130,Ultrasound Guided Puncture

 



 SAG: BPTM130,soft tissue biopsy ultrasound training block,blue phantom biopsy phantom,ultrasound guided biopsy phantom,ultrasound puncture training phantom,medical ultrasound simulation block,ultrasound tissue simulator