Silicone Sciatic Nerve Injection Training Module,HMQ-SNM QC Assessment

Mode:HMQ-SNM

Type:QA-Phantom

Contact:   ken@hkmedqc.com

The simulation model of the sciatic nerve provides healthcare professionals and medical students with a highly realistic clinical training experience. It is made of high-molecular materials with acoustic properties consistent with human tissues, offering a realistic touch and clear imaging. It supports repeated puncture practice, helping learners quickly master the anatomical structure, surface positioning, and puncture block techniques under ultrasound guidance of the sciatic nerve.
The model is applicable for teaching in multiple scenarios such as anesthesiology, pain management, neurosurgery, and rehabilitation medicine. It can fully simulate the entire process of ultrasound equipment operation, probe positioning, nerve recognition, needle path planning, and simulated injection. The self-repairing tissue can withstand repeated punctures by biopsy needles / puncture needles, and the puncture path is clearly visible, facilitating the assessment of needle insertion depth and operation accuracy. It supports customized adjustments to match different clinical training needs.

Key Product Features:  

- **Realistic Material Simulation**: Constructed from advanced high-molecular polymer materials, offering skin texture and muscle elasticity closely mimicking human tissue.  

- **Authentic Tactile Feedback**: Features lifelike skin feel and strong needle insertion resistance, combined with high durability and self-healing properties to minimize visible needle marks after repeated use.  

- **Accurate Anatomical Structure**: Internally embedded with simulated bony landmarks—including the anterior superior iliac spine, posterior superior iliac spine, sacrum, and greater trochanter—providing a scientific basis for precise injection site localization.  

- **Support for Repeated Practice**: Designed with robust construction to withstand prolonged, high-frequency use by multiple students without requiring frequent component replacement.  

 

Primary Functions & Applications:  

- **Muscle Injection Training**: Supports injection techniques for the gluteus maximus, gluteus medius, gluteus minimus, and vastus lateralis muscles.  

- **Sciatic Nerve Avoidance Training**: Internally delineates the sciatic nerve pathway, enabling students to learn how to prevent permanent nerve damage or paralysis caused by accidental needle penetration.  

- **Fluid Infusion Capability**: Most advanced models support real liquid injection and feature dedicated drainage tubes for full-process simulation.  

 

Silicone Sciatic Nerve Injection Training Module,HMQ-SNM QC Assessment

Silicone Sciatic Nerve Injection Training Module,HMQ-SNM QC Assessment

Silicone Sciatic Nerve Injection Training Module,HMQ-SNM QC Assessment

Silicone Sciatic Nerve Injection Training Module,HMQ-SNM QC Assessment
Note:
1. Use only standard ultrasound coupling gel and puncture/biopsy needles during training. Do not use sharp or contaminated tools to avoid damaging the modl tissue.
2. Wipe the model surface with a soft dry cloth after each use. Avoid direct sunlight, high-temperature environments, and contact with corrosive chemicals to prevent matering.
3. Avoid excessive repeated punctures in the same area. It is recommended to rotate practice regions to extend the model's service life.
4. Store the model in a coo-temperature environment. Avoid heavy pressure or contact with sharp objects to prevent deformation or damage.
5. This model is intended for medical teaching and training only and must not be used al diagnosis or patient treatment.


 SAG: Sciatic nerve model,Ultrasound guided puncture training,Nerve block simulator,Anesthesiology training phantom,Self-healing tissue model,Regional anesthesia practice,Medical education mannequin