QIBA DWI Diffusion Phantom NIST Traceability ADC Calibration Phantom 1.5T/3T MRI Quantitative Imaging Phantom,It is widely used in the standardization of magnetic resonance diffusion quantitative imaging. The product name will be uniformly referred to as "CaliberMRI", but the industry still uses the old name "QalibreMD".

QIBA DWI Diffusion Phantom,CaliberMRI Diffusion imaging phantom

Core Strengths

-NIST traceable standard parameters
Inbuilt 13 gradient concentration PVP solution bottles (0%–50%), covering the physiological ADC range of human tissues, with the diffusion coefficient calibrated by the National Institute of Standards and Technology (NIST) of the United States.
-Meets QIBA DWI compliance requirements
Complies with the QIBA diffusion imaging standards, and is a recognized reference model for multi-center clinical trials and pharmaceutical companies' image endpoint assessment.
-Compatible with mainstream 1.5T and 3T magnetic resonance equipment
Sphere outer diameter 194mm, compatible with clinical and research MRI from brands such as Siemens, GE, and Philips.
-Reserved temperature detection interface
ADC values are affected by temperature, supporting real-time temperature measurement, completing temperature correction, and ensuring measurement accuracy.
-Accompanied by qCal-MR® automatic quality control analysis software
Automatically delineates ROI, calculates ADC deviation, generates standardized reports, and realizes cross-device and cross-center data horizontal comparison.


Technical Specifications

Shape: Spherical mold, outer diameter 194 mm
Internal: 13 replaceable sample bottles, PVP concentration gradient from 0% to 50%
Supplementary: Official reference calibration data at multiple temperature points
Applicable field strength: 1.5T, 3T medical magnetic resonance

Diffusion magnetic resonance imaging can provide information on the progression or remission of tumors, and is often used to assess acute ischemic stroke. It is also an important means for diagnosing early cerebral infarction. To achieve targeted longitudinal analysis of tumors and neurological conditions, the QalibreMD quantitative magnetic resonance diffusion module was developed through the joint efforts of the Radiological Society of North America (RSNA), the Quantitative Imaging Biomarker Alliance (QIBA), the National Cancer Institute (NCI), and the National Institute of Standards and Technology (NIST). Through the standards established by this module, you can evaluate the performance of magnetic resonance scanners when measuring apparent diffusion coefficient (ADC). Currently, the QIBA DWI module, the qMRI diffusion imaging module, and the QalibreMD diffusion imaging module can be installed on all 1.5T and 3T detector coils used for imaging of the head and trunk.

The QalibreMD products are not merely simple imaging modules. They provide real and meaningful execution standards for the determination of quantitative biomarkers. To ensure that researchers and patients can benefit to the greatest extent from the MRI equipment, it is necessary to guarantee the high accuracy and good repeatability of the imaging results. Establishing unified and standardized standards for MRI produced by different medical institutions and scanners produced by different manufacturers is particularly important for the comparison of imaging results and improving the patient experience. The QalibreMD series of modules were jointly developed by institutions including the International Society for Magnetic Resonance in Medicine (ISMRM), the National Institute of Standards and Technology (NIST) of the United States, the Radiological Society of North America (RSNA), the Quantitative Imaging Biomarker Alliance (QIBA) under the RSNA, and the University of California, San Francisco. They provide real and meaningful execution standards for quantitative biological imaging biomarkers. A series of modules including patented diffusion-weighted imaging (DWI), multi-functional multi-parameter, breast and prostate, etc., have been certified by the National Institute of Standards and Technology (NIST) of the United States. They will provide precise and reliable guarantees for your medical research and patient care!

QIBA DWI Diffusion Phantom product picture

QIBA DWI Diffusion Phantom,CaliberMRI Diffusion imaging phantom

QIBA DWI Diffusion Phantom,CaliberMRI Diffusion imaging phantom

QIBA DWI Diffusion Phantom,CaliberMRI Diffusion imaging phantom




 SAG: QIBA DWI,QIBA DWI phantom,CaliberMRI phantom,qMRI diffusion imaging phantom,QalibreMD diffusion imaging phantom,diffusion imaging phantom,QalibreMD of the United States,MRI diffusion QA phantom,quantitative imaging phantom